Disused back boilers pose blast threat

Following five back boiler blasts, heating professionals are being urged to follow HSE guidelines concerning disused solid fuel boilers left behind fireplaces.
Disused back boilers pose blast threat
The HSE is aware of five cases in the last five years involving exploding back boilers, where a fire is lit in front of a solid fuel boiler and has issued a safetyalert

In November 2007, a woman died after a back boiler blast in Twyning, Gloucestershire. In several cases, an explosion occurred when a fire was lit for the first time following a heating system conversion.
The back boiler unit typically consists of a fire grate, which carries the combustible material (e.g. coal, and a water chamber 'surrounding' it).

As the units are difficult to drain completely residual water left in the boiler will turn to steam when heated.

In tests carried out in 2002, the top and sides of a solid fuel back boiler, without circulating water, reached temperatures in excess of 7000C. Previous advice recommended that a disused back boiler left in situ must be left in a condition that prevents an unsafe level of pressure building up in unit.

The HSE recommends that at the decommissioning stage, the system should have been drained and redundant pipework removed along with, the back boiler itself. If not removed the boiler should be left in a 'vented' or 'open' condition.

The HSE said 'In some cases the decommissioning may have been carried out by an individual, or heating or building organisations that were unaware of the potential problem or had not seen the advice'.

Other dangers can arise with continued use of a fireplace and redundant back boiler even if it is vented, for instance if connected pipework is left in situ, corrosion of the water jacket sidewalls may allow flue gases to enter the pipework and spread through the property.

HETAS the independent DEFRA-recognised association responsible for testing and approving domestic solid fuel burning appliances, said in a statement 'The only positively safe and reliable way to proceed, when a solid fuel back boiler is no longer needed and the customer wants to continue using the fireplace, is to totally remove the back boiler installation by breaking up the chamber that used to carry the hot water system and removing any pipe work.

'When an open fire is left in use (or could be brought back into use) a replacement Milner fire back needs to be installed to ensure that the fire can be safely used'.

12 May 2008

Comments

Already Registered?
Login
Not Yet Registered?
Register

UK heat pump sales reach record high in 2025, but more must be done to meet targets

New data published by the Heat Pump Association UK shows that heat pump sales reached another record high in 2025, with over 125,000 units sold in the UK, a 27% increase on the previous year....

  17-Feb-2026

Fernox to exhibit at MOSTRA CONVEGNO EXPOCOMFORT 2026

Leading water treatment company, Fernox, is pleased to be exhibiting at Mostra Convegno Expocomfort (MCE) 2026 in Milan, Italy. Taking place 24th- 27th March, Fernox will showcase its comprehensive range of chemical water treatment solutions for ...

  17-Feb-2026

STOKVIS R600

CONDENSING ULTRA LOW NOx PREMIX COMMERCIAL BOILER
  10-Jan-2019
Heating & Ventilating Review is the number one magazine in the HVAR industry. Don’t miss out, subscribe today!
Subcribe to HVR

Diary

HVR Awards 2026
https://www.heatingandventilating.net/disused-back-boilers-pose-blast-threat-