Vaillant launches new flue safety training

Vaillant is using its commercial training programmes to bring installers of light commercial appliances up to speed with flueing regulations.
Gas engineers are legally required to check the flue after carrying out any work on the boiler, which includes making a visual inspection to confirm that the flue is safe. The regulations concern fan-flued gas appliances which are frequently installed to maximise internal space. The flues to these boilers are, in many cases, routed through voids in ceiling spaces and behind stud walls.

John Bailey, commercial heating & systems director at Vaillant said: 'When installers fit a boiler they have to be clear that it can be used without it constituting a danger to anyone and that requires them to confirm that the flue is safe. Moreover, every time the boiler is serviced the engineer must be able to check that the flue is still safe, that it is continuous and properly supported throughout its length and that all joints are correctly assembled and are appropriately sealed.'

As a consequence, new regulations (announced in HSE bulletin OPSTD 10-2010 which came into force on 1 January 2011) now require inspection hatches to be available in ceilings or stud walls to give engineers proper access to the flue. Homeowners or landlords have until December 31st 2012 to arrange for inspection hatches to be installed. Any gas engineer working on such systems after January 1st 2013 will have to advise the homeowner that the system is 'at risk' and, with the owner's permission, will need to turn off the gas supply to the boiler so that it cannot be used.

Until then however, where no inspection hatches are fitted, engineers can carry out a simple risk assessment which should ensure that the risk from exposure to CO is managed in the short-term. This risk assessment includes looking for signs of leakage along the flue route by carrying out a flue combustion analysis check and checking for the presence of suitable carbon monoxide alarms and installing such alarms where they are not already fitted. As long as the boiler passes the series of safety checks and the risk assessment does not identify any concerns about its safety, it can be left on.

For further information on Vaillant's commercial training course click here.

Follow HVROnlineEditor on Twitter
1 August 2011

Comments

Already Registered?
Login
Not Yet Registered?
Register

Insulating EU homes could reduce energy demand by 44%

A new study released by Buildings Performance Institute Europe (BPIE) shows that improving the insulation of existing residential buildings in the EU would significantly contribute to securing the bloc’s energy independence and achieving he EU target of reaching climate neutrality by 2050.

Improved insulation of EU residential buildings would result in a reduction of energy demand for heating in buildings by 777 TWh, or 44% compared to 2020: 46% in gas savings, 44% in heating oil savings and 48% in coal savings.

  19-Jan-2023

Hot water for healthcare

Recent research by the University of Exeter sets out the scale of the challenge the NHS faces if it is to achieve sustainability targets set under the government’s net zero plan by 2040, a full decade ahead of the wider commercial sector....

  19-Jan-2023

If you need to open a Solenoid Valve manually, you need a SVOM!

If you need to open a Solenoid Valve manually, you need a SVOM!
  22-Oct-2021
Heating & Ventilating Review is the number one magazine in the HVAR industry. Don’t miss out, subscribe today!
Subcribe to HVR

Diary