Installers could unknowingly be in breach of British Standards when it comes to recirculating systems, according to plumbing systems manufacturer Uponor.

Plumbing applications manager at Uponor, Mark Dowdeswell, said: 'The latest amendments to the standards within the UK building regulations, date back to 2012, following the publication of the BS EN 806-5 and BS 8558. What is particularly interesting is that as a result of the amendments, a number of products have now been classified as unsuitable for use in recirculating systems.'

Mr Dowdeswell continued: 'It is important to understand these amendments and where the changes have been applied. Crucially, there are a number of fundamental changes that installers and specifiers should be aware of. BS 7291 remains the same, and therefore piping systems built to this standard are not suitable for re-circulating systems. Under the BS ISO 15875 – products designed to this standard, can be applied to recirculating systems.

'A further key change, according to the British Standards, is that pipework in recirculating systems must be capable of handling water temperatures of 65degC ±5degC and must also feature a high limit cut-off facility to ensure safety is maximised. Furthermore, the BS EN 21003 standards for multi-layer piping systems also demand the same requirements, with a high limit cut-off facility, and pipework capable of handling hot water temperatures of 65degC and above.

'The changes within the British Standards are designed and formed as a result of industry consultation and the changes have been made to ensure safety standards are met and maintained throughout the marketplace. The potential ramifications of applying the incorrect piping to a recirculating system are huge when you consider the water temperatures which they carry,' he added.

'One of the key reasons for this, is for the prevention of legionella, known to grow most acutely when water temperatures are between 25degC and 500degC - outside of these ranges the bacteria either remains dormant or is killed off.'

Mr Dowdeswell concluded: 'My advice to any installer therefore is to have a clear understanding of the changes and the relevance to them, and speak to either their local merchant or pipe manufacturer for advice ensuring safety as standard, in all applications.'

14 May 2015

Comments

Already Registered?
Login
Not Yet Registered?
Register

New BESA guidance will ‘revolutionise building air quality’

The Building Engineering Services Association (BESA) has launched a new specification for ventilation hygiene as part of its ongoing efforts to minimise the risk posed by contaminated indoor air to human health and well-being....

  18-Apr-2024
ACR News

Vapac Electrode Boiler launched

As the exclusive Vapac distributor in the UK, Humidity Solutions has announced the launch of the NEW Vapac Electrode Boiler, which incorporates advanced technology to minimise water and energy wastage....

  18-Apr-2024

STOKVIS R600

CONDENSING ULTRA LOW NOx PREMIX COMMERCIAL BOILER
  10-Jan-2019
Heating & Ventilating Review is the number one magazine in the HVAR industry. Don’t miss out, subscribe today!
Subcribe to HVR

Diary

HVR Awards 2024