PRV misuse named as cause of avoidable boiler breakdown

Martyn Bridges, director of technical communication and product management at Worcester Bosch, believes that boiler breakdowns caused by the incorrect use of the Pressure Relief Valve (PRV) component to drain a heating system down, could be avoided indefinitely.

Mr Bridges explains: “It’s not unusual for PRVs to last the lifetime of a boiler if used correctly, as a PRV isn’t a wearable part. If a PRV is used incorrectly though, it can quickly become irreparably damaged and lead to a breakdown. 

“Unfortunately, PRVs are frequently used erroneously to drain heating systems down. This isn’t what they are designed for and can cause complications, yet due to PRVs being situated at the bottom of a boiler, in addition to being attached to a permanent pipe, it can be tempting to drain a system this way.”

When using a PRV to drain a system, any contaminants in the heating system are drained through the valve itself and end up on the seating of the valve where the valve should re-seal and shut off again. 

“The most noticeable sign of this is apparent when the heating system is put back into operation and you can see water dripping periodically from the valve outside. For the homeowner, this means they must re-pressurise the heating system from time-to-time, but ultimately, the PRV needs to be replaced.”  

Mr Bridges concludes: “The system should contain drain-off valves at all low points in the system, and all drops to radiators from above. These are the only places that a system should really be drained from.”

29 October 2018

Comments

Already Registered?
Login
Not Yet Registered?
Register

New BESA guidance will ‘revolutionise building air quality’

The Building Engineering Services Association (BESA) has launched a new specification for ventilation hygiene as part of its ongoing efforts to minimise the risk posed by contaminated indoor air to human health and well-being....

  18-Apr-2024
ACR News

Vapac Electrode Boiler launched

As the exclusive Vapac distributor in the UK, Humidity Solutions has announced the launch of the NEW Vapac Electrode Boiler, which incorporates advanced technology to minimise water and energy wastage....

  18-Apr-2024

STOKVIS R600

CONDENSING ULTRA LOW NOx PREMIX COMMERCIAL BOILER
  10-Jan-2019
Heating & Ventilating Review is the number one magazine in the HVAR industry. Don’t miss out, subscribe today!
Subcribe to HVR

Diary

HVR Awards 2024