Know what you want? Try our 'Supplier Directory' 

Fans: Pressures on the fan that helps save lives

Until recently a pressurised means to control fire smoke in medium rise residential buildings was considered too expensive, but an integrated fan design solution has been produced expressly to protect lives in the event of fire.
Two recent fires in residential flats have focused attention on the dangers of such blazes and their inherent difficulties for the fire service. The fire at Lakanal Flats in Camberwell and the 15-storey Shirley Towers in Southampton caused fatalities and in both cases the flames and particularly smoke rapidly spread out of control.

The problem is that no matter how structurally resilient a building is made, if a fire breaks out and renders the primary means of escape, stairways and elevators, unusable, the building quickly becomes unsafe.


The dilemma of how to evacuate a building, if exits are jeopardised, remains the foremost safety issues for occupants working and living in high rises, and even low rises today.

A pressure differential system - commonly known as pressurisation system - is the only solution where the objective of the design is to keep smoke out of the escape routes altogether, by producing pressure and/or air velocities across doors on the fire-affected floor, using a supply air fan.

The design of the air system, based on European standards, is pure fan application engineering, hence it is important designers understand the principles of fan engineering. The stairwell must be pressurised at the earliest stages of a fire.
It has become the system of choice for high-rise buildings in most countries outside the UK and indeed for many prestigious buildings in the UK. Fläkt Woods, in collaboration with fire systems design specialists Fire Engineering Associates and Interactive Special Projects, has just launched the Smoke Angel - which heralds a new, cost-effective pressurisation system.

The appliance is automatically activated to clear hot smoke from within the stairways, with operation initiated by smoke detectors located within the common corridors or lobbies. Pressurisation begins within approximately 20 seconds of the start of a smoke detector. As it takes an average of 4-10 minutes, in urban areas, for the fire department to arrive, the new fan is HT rated, and reversible, so attending fire fighters can then use the control panel to choose the pressurisation/ smoke exhaust option that is most appropriate to the situation.

The fan is temperature rated to F300, for operation at 300ºC for two hours and CE marked. It includes an integrated fan module with an automatically opening ventilator, a differential pressure switch and, when required, a smoke detector.

Paul Wenden, engineering director of Fläkt Woods states: 'Traditionally in the UK, smoke control in residential medium rise buildings has been provided for by natural ventilation, fitting vents with a pre-determined free area, to allow the smoke to exhaust the building either directly, or via a vertical smoke shaft of the same area. These systems are very prone to external wind-induced positive pressures and as such are unreliable as a life-saving system. In addition, in any form of ventilation system the smoke will have to enter and pass along the escape routes to reach the vents, contaminating the escape route in the process. Pressurisation is the only system that avoids this weakness.'

The ventilator opens and the fan starts automatically once the smoke detector is triggered, raising the pressure in the stairwell and preventing fire smoke from entering the vertical part of the escape route. When necessary, additional automatically operated air relief is provided.

Thanks to its compact external dimensions, it is suitable for use in new build as well as many refurbishment projects. For ease of design, it is pre-designed with constant air volumes that work for stairwells of many different heights.

'Not only is the product concept already proven and preferred overseas but we are able to provided site surveys before proposing the complete solution - right through to system commissioning - all endorsed by Fläkt Woods,' Wenden concludes.
1 June 2010

Comments

Already Registered?
Login
Not Yet Registered?
Register

FETA welcomes guests to Annual Luncheon

The 2024 FETA Annual Luncheon took place on Thursday 11th April and attracted guests from across the heating, ventilation, building controls, refrigeration and air conditioning industries as well as individuals from related institutions, ...

  25-Apr-2024

Prizes galore to be won on Conex Bänninger’s interactive stand

Conex Bänninger, a global leader in the manufacture of high-quality fittings, valves and accessories, will have an enhanced interactive stand (5D19) at InstallerShow 2024....

  25-Apr-2024

STOKVIS R600

CONDENSING ULTRA LOW NOx PREMIX COMMERCIAL BOILER
  10-Jan-2019
Heating & Ventilating Review is the number one magazine in the HVAR industry. Don’t miss out, subscribe today!
Subcribe to HVR

Diary

HVR Awards 2024