Know what you want? Try our 'Supplier Directory' 

Air source heat pump solution for heating & hot water to Surrey Sports Pavilion

Rinnai has given a local community’s much-loved sports pavilion a replacement DHW system which upgrades from its old cylinder system and provides the same peak-time capacity with significantly reduced energy costs along with much lower emissions through utilising the Rinnai R290 heat pump system.

Rinnai offered a choice of solutions all with capital, operational and carbon modelling as part of the offering, so that the decision makers could select the optimum solution for their needs. Based upon the data the site specifically requested an Air-Source Heat Pump replacement.

For bespoke design support services contact us today https://www.rinnai-uk.co.uk/contact-us/help-me-choose-product

Rinnai offered a choice of solutions all with capital, operational and carbon modelling as part of the offering, so that the decision makers could select the optimum solution for their needs. Based upon the data the site specifically requested an Air-Source Heat Pump replacement.

As a part of the bespoke design service offered by Rinnai three possible solutions were put forward, each with differing recovery times ranging from between two and four hours, with the 2000L in storage staying consistent with the old system’s capacity.

After full consultations with the site and the contractor, the system chosen was the 40kW R290 air source heat pump system. Despite the two other possible systems offering quicker recovery periods the client opted for one single heat pump unit. An additional factor governing the decision was the fact that the 40kW R290 system, incorporating 2 x1000 L cylinders, emitted less carbon and was more economical to run in the long term

Cumulative Running Costs (OPEX) comparing a H1 and a H3 system for DHW

Cumulative Running Costs (OPEX) comparing a H1 and a H3 system for DHW

This graph shows the cumulative running costs of each of the three possible systems across a 5-year period. As shown from the data the original system is significantly more expensive to run compared to the H3 systems. With a £46,772.13 or 170% increase compared to the 23kW R290 systems and a £48,251.10 or 186% increase compared to the 40kW R290 system by year 5.

The successful implementation of the Rinnai R290 air source heat pump system at the Surrey Sports Pavilion demonstrates the effectiveness of Rinnai’s bespoke design services and complete packaged solutions. By upgrading to a more efficient and environmentally friendly system, the pavilion now enjoys reduced carbon emissions, while maintaining the necessary capacity for peak-time demand. This project highlights Rinnai’s commitment to providing tailored solutions that meet the specific needs of all type of buildings to experience this service for your next project contact us today https://www.rinnai-uk.co.uk/contact-us/ask-us-question

Comparison of Energy Prices of National Gas and National Grid Electricity Between 2025 & 2050

Energy Prices of National Gas and National Electricity Grid

Energy Prices of National Gas and National Electricity Grid

UK energy strategists believe that clean and sustainable electrification is presently one of the best modes of reducing carbon emissions, maximise efficiencies and to also lower end-user customer costs.

 

19 February 2025

Comments

Already Registered?
Login
Not Yet Registered?
Register

Families to get more choice over home upgrades

Homeowners are set to have more choice over ways to access heating systems and bring down costs under proposals being considered as part of the Warm Homes Plan – helping to deliver on the government's milestone of higher living standards as part of ...

  30-Apr-2025

Ideal Heating Commercial takes extra care with the heat network at Huddersfield specialist housing development

Ideal Heating Commercial POD Heat Interface Units (HIUs) and Evomax 2 condensing boilers have been installed into Ash View Extra Care in Huddersfield as part of a heat network designed to heat the 50 one and two bedroom flats and communal areas, ...

  30-Apr-2025

STOKVIS R600

CONDENSING ULTRA LOW NOx PREMIX COMMERCIAL BOILER
  10-Jan-2019
Heating & Ventilating Review is the number one magazine in the HVAR industry. Don’t miss out, subscribe today!
Subcribe to HVR

Diary

HVR Awards
BESA Industry Awards